Detection of natural and simulated periodontal defects using Cone-Beam computed tomography and digital intraoral radiography

Basit öğe kaydını göster

dc.contributor.author Mısırlı, Melis
dc.contributor.author Aksoy, Seçil
dc.contributor.author İçen, Murat
dc.contributor.author Tümer, Hayriye
dc.contributor.author Bilginaylar, Kani
dc.contributor.author Karaoğluları, Atilla
dc.contributor.author Orhan, Kaan
dc.date.accessioned 2022-06-20T13:56:22Z
dc.date.available 2022-06-20T13:56:22Z
dc.date.issued 2022-02
dc.identifier.citation Misirli, M., Aksoy, S., İçen, M. ., Tumer, H., Bilginaylar, K., Karaoglulari, S., Berberoglu, A., & Orhan, K. (2022). Detection of Natural and Simulated Periodontal Defects Using Cone-Beam Computed Tomography and Digital Intraoral Radiography. Journal of Contemporary Medical Sciences, 8(1). https://doi.org/10.22317/jcms.v8i1.1126 tr_TR
dc.identifier.uri https://www.jocms.org/index.php/jcms/article/view/1126
dc.identifier.uri http://hdl.handle.net/20.500.11787/7215
dc.description.abstract Objective: In this study, it was aimed to compare the diagnostic value of cone beam computed tomography (CBCT) and digital intraoral periapical imaging methods in the diagnosis of periodontal defects, and the comparison of observers practicing dentistry in the field of periodontology and 3 other observers specialized in various branches was evaluated. Methods: 7 dry mandible and 5 dry maxilla were used in this study. A total of 111 artificial and natural defects (dehiscence, furca, fenestration, vertical defects) on the anterior, premolar and molar region were imaged with digital imaging techniques using different exposure parameters and scanned with CBCT. Results: According to the results of this study, CBCT is a more reliable method in the evaluation of all periodontal defects compared to CCD and PSP. 60 and 70 kVp with 0.01 irradiation time in CCD and 70 kVp 0.25 irradiation time in PSP is not suitable for detecting defects owing to high contrast. In the evaluation of periodontal defects, there was no single observer who had good results, different imaging methods and varying results were obtained in different defects. Conclusion: This study showed that the CBCT method has some diagnostic value for detecting all natural and simulated periodontal defects but it should only be used in cases where clinical evaluation and conventional radiographic imaging do not provide the information necessary for an adequate diagnosis and proper periodontal treatment planning. tr_TR
dc.language.iso eng tr_TR
dc.publisher Naba'a Al-Hayat Foundation for Medical Sciences and Health Care tr_TR
dc.relation.isversionof 10.22317/jcms.v8i1.1126 tr_TR
dc.rights info:eu-repo/semantics/restrictedAccess tr_TR
dc.subject Vertical defects tr_TR
dc.subject Cone beam computed tomography tr_TR
dc.subject CCD tr_TR
dc.subject PS tr_TR
dc.subject Exposure parameters tr_TR
dc.title Detection of natural and simulated periodontal defects using Cone-Beam computed tomography and digital intraoral radiography tr_TR
dc.type article tr_TR
dc.relation.journal Journal of Contemporary Medical Sciences tr_TR
dc.contributor.department Nevşehir Hacı Bektaş Veli Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Radyolojisi Anabilim Dalı tr_TR
dc.contributor.authorID 25225 tr_TR
dc.identifier.volume 8 tr_TR
dc.identifier.issue 1 tr_TR
dc.identifier.startpage 38 tr_TR
dc.identifier.endpage 43 tr_TR


Bu öğenin dosyaları

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster